High Pressure Filters

High Pressure Filters

Series HP

Standard Features

  • Bypass valve – to protect filter element, standard setting is 25 PSID (1.72 Bar). Other settings are available.
  • 360° mechanical differential indicator – provides gradual warning of dirty element before bypass valve opens. Standard setting is 20 PSID (1.38 Bar) for full “œred” indication. Other settings are available.
  • Mounting holes for convenient installation.
  • Drain plug.
  • Self-aligning element for easy replacement.
  • T-type construction for more efficient contaminant removal.
  • Cycle tested at 3900 PSI (269 Bar) for 1,000,000 cycles. 
  • Filter retention: 5 micron nominal, B5 = 2.2 10 micron nominal, B10 = 2.1 3 micron absolute, B3 = 200 12 micron absolute, B12 = 200

OPTIONAL FEATURES

  • 360° electro-mechanical differential indicator. Provides gradual warning and electrical signal before bypass opens.
  • Differential taps for remote indicator location.

APPLICATIONS NPFT

The HP series is designed for high pressure hydraulic systems that require fine filtration. These filters come in three standard sizes with continuous working pressure of 3000 PSI (207 Bar) and flows to 60 GPM (227.1 L/min.).

12_high_pressure_filter.psd

12_1.psd

12_2.psd

Series HP

13_1.psd

13_2.psd

13_3.psd

Series B

14_high_pressure_filter.psd

FEATURES 

  • Built-in bypass valve.
  • In-line type designed for 3000 PSI (207 BAR) operating pressure.
  • Inexpensive.
  • Low cost replacement parts.
  • 40 nomial micron retention.
  • 3 & 12 micron absolute.

APPLICATIONS

Designed to meet today’s requirements for good protection of hydraulic components on machine tools, industrial equipment, construction machinery, farm equipment, or wherever close tolerance parts would be damaged by contaminated oil.

OPERATION

A large flow-area bypass valve, built into the head of the filter, cracks at 35 PSI (2.45 BAR), preventing damage to element if flow is restricted due to contamination. Mounting filter at pump discharge port protects all valves, cylinders, motors and rotary actuators.

Options 

  • Taps for Differential Pressure Indicator 
  • E.P.R. amd Viton available 
  • Optional porting available

14_2.psd

SPECIFICATIONS

Model B 14-2:

Capacity: 20 GPM (75.7 L/min.)
Filtration: 40 micron nominal 75 micron absolute B
40 = 96
Element Area: 26 in.
2 (167.7 cm2)
Element Type: Ribbon lamination

Model B 14-2A:

Capacity: 20 GPM (75.7 L/min.)
Filtration: 12 micron absolute 5 gram holding capacity B
12 = 200
Element Area: 94 in.
2 (606.5 cm2)
Element Type: Micro Glass

Model B 14-2B:

Capacity: 15 GPM (56.8 L/min.)
Filtration: 3 micron absolute 4.8 gram holding capacity B
3 = 200
Element Area: 94 in.
2 (606.5 cm2)
Element Type: Micro Glass

200 PSID Collapse

3000 PSID Collapse Available

14_1.psd

Series B

15_1.psd

15_2.psd

15_3.psd